Variable Frequency Audio Video Test Equipment Environmental Considerations Output Capacity 20KVA
Product information:
This product is widely used in various fields, and provide the
power supply system of the customer solutions from power
environmental considerations, optimization of load collocation,
power matching selection, designed to fit the needs of
manufacturing, lean and efficient, timely maintenance and perfect,
can completely meet the needs of customers.
Technical Parameters:
Item | Parameter | |
Output capacity | 20KVA | |
AC input | ||
Phase number | Three phase | |
Waveform | SINEWAWE | |
Voltage | 380V±15% | |
Frequency fluctuation range | 50HZ or 60HZ±15% | |
power factor | ﹥0.9 | |
DC input | ||
Phase number | Three phase | |
Waveform | SINEWAWE | |
Low gear voltage | 0-260V continuously adjustable | |
High gear voltage | 0-520V continuously adjustable | |
Frequency | 60HZ,50HZ,40-499.9HZ continuously adjustable | |
Frequency stability | ≤0.01% | |
High gear maximum current (A) | 55.6A | |
Low gear maximum current (A) | 27.8A | |
Whole machine performance | ||
Power regulation rate | ﹤1% | |
Load regulation rate | ﹤1% | |
Waveform distortion | ﹤2% | |
Efficiency | ﹥90% | |
Response time | ≤2ms | |
Crest Factor | 3:1 | |
Display | ||
Display interface | Digital LED display | |
Voltage ` | 4 digits, digital voltmeter, resolution 0.1V | |
Current | 4 digits, digital ammeter, resolution 0.1A | |
Power | 4 digit, digital wattmeter | |
Frequency | 4 digit number, digital frequency meter |
The order of explanation is from left to right, from top to bottom,
and is described step by step:
1. Output frequency indication table: The digital display shows the
output frequency to one decimal place.
2. Output voltage indication table: The digital display shows the
output voltage value.
3. Load current indication table: The digital display shows the
output current value.
4. Load watt indicator table: digital display output power value.
5. Power switch button: The switch start button.
6. Power-on reset switch: The inverter trips due to overload or
open circuit. When the alarm sounds, press this button to restart.
7. Frequency Dip Switch: Fixed frequency 40.0-499.9HZ programmable
(dial) setting.
8. Output voltage switch: second gear 0-150V or 0-300V.
9. Standard voltage output trimming button: Ten-turn fine-tuning
switch, which can be fine-tuned to get the standard voltage you
need.
10. Three-phase output current display switch: can display the
output current value of each phase. (Only for three-phase output
models).
11. Output universal socket: load below 10A. (Only for single-phase
500W~5KVA inverters)
12. POWER: Main power switch.
13. O/P: Output load switch.
14. Input the terminal block.
15. Output terminal block.
Operation Instructions
1. First cut the power switch to the OFF position.
2. Please check the integrity switch of the equipment before use,
and rotate the button display of various functions to ensure that
there is no looseness.
3. Check if the input power is within the specifications and then
switch the main power switch to the ON position.
4. Set the output frequency. The indicated frequency on the dial is
the output frequency. When setting the hundred-digit frequency, you
need to press the OFF/RESET button first.
5. Press the start switch: Please turn off the output switch before
pressing this switch.
6. Adjust the output voltage: Cut the output voltage switch to the
desired gear position.
(a) Lo-V gear 0-150V PS: Use this file below 150V.
(b) Hi-V gear position 0-300V PS: Use this file for 150V or more.
7. Connect the load input line and turn on the output switch to get
the standard power supply for the value displayed on each function
display.
8. The machine is overloaded or short-circuited. When overload or
short circuit, the protection circuit immediately cuts off the
output power, and the buzzer alarms. Please turn off the load
first, then press the reset switch (OFF/RESET) to stop the alarm.
Then press the start switch to start power supply. Check the load
condition, confirm that there is no abnormality, and then turn the
load switch back on.
9. Press OFF-RESET during operation to cut off the output voltage.
Abnormal condition | Solution |
Can not boot | 1. whether there is a power outage or not |
Cut "NFB to" 0N | |
3. Check the power cord, plug, socket | |
4. Check the fuse | |
The output frequency is displayed normally. But the voltmeter and ammeter display as "0" | 1. Turn the power switch to OFF |
2.Adjust the output voltage to zero switch | |
3. 3. Cut the power switch to OFF | |
The output frequency is normal, but the voltage and ammeter are displayed as "0" and the warning sounds. | 1. Check and reduce the load current |
2. Press the RESET switch | |
3. Wait for the machine to delay starting | |
4. Re-operation |
Warning:
1. The inverter has different installation standards due to
different capacity. Please follow the specifications of your
inverter.
Choose the appropriate way to wire, especially pay attention to the
wire diameter must comply with the regulations.
2. Please pay attention to the input end of the inverter, avoid
sharing a switch with other equipment and close to the city power
supply head.
3. Confirm that the input power supply voltage meets the input
rated voltage of the inverter.
4. Please turn off the power when wiring, and do not operate the
fire line for safety.
5. Please select the size of the wiring wire according to the
regulations of the electrician, and pay attention to the screw
tightening.
6. Please use O-terminal construction for the terminal.
7. Please ensure that the grounding wire of the inverter is
implemented.
8. The input power cannot be connected to the output power supply.
9. The semiconductor components on the internal control board are
susceptible to static electricity and damage. Do not touch the
control board.
10. The operating environment and wiring work of the inverter have
a direct impact on the normal function of the inverter, its service
life and even the safety. Therefore, be sure to follow the above
requirements for installation and wiring.
Guangzhou HongCe Equipment Co., Ltd.
Guangzhou HongCe Equipment Co., Ltd (hereinafter referred to as HongCe) is located in Guangzhou, China, since 2003, engaged in developing and providing test equipment and detection system for electronic & electrical products, house appliances and other products. HongCe is professionally dedicated in providing laboratory testing equipment and production line testing system, we are now the high-tech enterprises with technical superiority and R & D capabilities in test instruments industry.
Our core technologies encompass vacuum, leak testing & automatic control, laboratory test equipment & solution. Our technical leader is an expert in leak detection, his more than 2 decades of experience are a great asset to our firm. Our technical team is comprised of wellexperienced engineers and technicians.
HongCe laboratory testing equipment are designed and manufactured as per the requirements of GB, IEC, EN, UL, VDE, BS, AS, ISO standards and etc. Our main products are: switch, plug, socket and coupler test equipment; mechanical strength impact test equipment; material fire hazard test equipment, enclosure protection test probes; waterproof and dustproof environmental testing equipment; household appliances testing equipment; wire and cable testing equipment; luminaires test equipment; electric tools test equipment; information technology and audio & video test equipment. Our products are widely used in domestic and worldwide measurement & certification institutions, inspecting mechanism, laboratories, export & import inspection and quarantine bureau, various production companies and etc. Our customer includes Bureau Veritas, CSA, ITS, UL, TUV Rheinland, TUV SUD, SGS and etc.
HongCe production line testing equipment are mainly customized according to client's workpieces, such as automatic leak testing system, gas recovery system, other tailor-made system based on vacuum & leak testing technology.