Rain Environmental Test Chamber for Enclosure Water Resistance Test
PX1/2 Vertical Rain Drop Test
1. Meet the requirement of IEC60529 standard IPX1 vertical rain
drop test and IPX2 15°inclination rain drop test.
2. Rainfull capacity: IPX1: 1 ±0.5mm/min
IPX2 : 3 ±0.5mm/min
3. Water drop chamber effective dripping area: 1000*1000mm, water
droping hole diameter: Φ0.4mm, hole distance: 20*20mm
4. Water drop chamber uses vaccum design, match with oxidation
alloy aluminium and high rust stainless steel material structure,
nozzle contact a brass tapered design, convenient in installation
and replace needle tip.
5. Rain drop device can automatically lift, nozzle is located in
200mm from the highest point of test sample, and equipped with
protection devices to ensure it would not drop too fast. It can
also lift manually.
6. With compressed air dry function, when the experiment is
complete but will drop out the excess water clean, avoid long time
water dirty jams needle tip.
7. Dc electric lifting motor drive, stainless steel wire rod,
pulley guide with locking nut lifting device.
8. Aluminum alloy and stainless steel fuselage; Hang to the wall or
four column equality lifting.
IPX3/4 Vertical Rain Drop Test
1. Meet the requirement of IEC60529 standard IPX3 water pouring
test and IPX4 water splash test.
2. The test sample will be put or installed on the center of the
half-round sinuous pipe and make the bottom of the test samples and
the oscillating axis in a horizontal position. During test, the
sample would spin around the center line.
3. Swing pipe standard configuration: R600mm and R1000mm two types.
Swing pipe inner diameter: Φ15mm.
DillΦ0.4 holes and make the water spray to the center.
The water pressure of the device entrance is equal to 10m water
level, spraying water pressure is 80-100kpa.
4. Water spraying pipe swing angle: 120º,180º,360º, Vertical sides:
60º,90º,175º.
Complete a swing(2*120º) time is 4S.
Complete a swing(2*360º) time is 12S.
5. Can manual default the test parameters, complete testing
automatically shut off the water supply and pendulum pipe Angle
automatic zeroing and automatic eliminate seeper, avoid scale
blockage needle tip.
6. Use Mitsubishi PLC, LCD panel test procedure control box,
stainless steel curved pipe, alloy aluminum frame, stainless steel
shell.
7. Servo drive mechanism, guarantee the pendulum pipe Angle of
precision, the overall pendulum tube structure for hang a wall.
Pendulum tube radiusmm | IPX3 | IPX4 |
Blowhole number | Total Flow | Blowhole number | Total Flow |
L/min | L/h | L/min | L/h |
400/500 | 25 | 1.8 | 108 | 37 | 2.6 | 156 |